Page 156

2013_NDC_PhysCatalog

COVIDIEN/KENDALL INFANT HEEL WARMER Provides a fast, safe, and economical means to apply just the right amount of heat to infant’s heel for blood sampling. Simply squeeze the pouch for instant activation. Heel warmer quickly reaches the proper temperature and maintains this temperature for several minutes. MH00002T has an adhesive tab for convenient attachment to the infant. MH00002N Infant Heel Warmer, No Adhesive lab equipment & accessories Blood Collection Products 154 Attachment Pad, 100/cs MH00002T Infant Heel Warmer, Adhesive Attachment Pad, 100/cs ARKRAY ASSURE® HAEMOLANCE PLUS® LANCETS Help protect healthcare professionals and patients from accidental needlestick injuries and cross-contamination. Designed to meet OSHA requirements for needlestick safety. The needle is shielded prior to and after use. Features a automatic lockout after use. Its rapid needle retraction promotes patient comfort. Needle depth control offers consistent sampling results. Haemolance Plus Safety Lancets are available in 28, 25, 21, and 18 gauge formats and 1.2 and 1.6 blade depth. 100/bx. 970112 Pediatric Flow Blades, 1.2mm Depth, Pink 970118 High Flow Lancets, 18G, 1.9mm Depth, Yellow, 970121 Normal Flow Lancets, 21G, 1.8mm Depth, Green 970125 Low Flow Lancets, 25G, 1.4mm Depth, Blue, 970128 Micro Flow Lancets, 28G, 1.6mm Depth, Light Blue 980125 980225 ARKRAY ASSURE® LANCE LOW FLOW LANCETS 980125 Low Flow 25G Lancets x 2mm, 100/bx 980225 Low Flow 25G Lancets x 2mm, 200/bx BD MICROTAINER® QUIKHEEL™ LANCET A safety-engineered product designed for heelsticks on babies and neonates. The simple one-handed activation releases a retractable surgical blade for precise, consistent incision. Provides sufficient blood flow to conduct low trauma sampling. 368100 QuikHeel Preemie Lancet, Pink, .85mm Incision Depth, 1.75mm Incision Length, 50/bx, 4 bx/cs 368101 QuikHeel Infant Lancet, Teal, 1.0mm Incision Depth, 2.5mm Incision Length, 50/bx, 4 bx/cs 7155 7142 7143 HTL-STREFA ACTI-LANCE SAFETY LANCET Easy to handle: intuitive activation, how firing force, no lancet loading required, 2 step operation only. Minimized pain: ultra sharp and silicon coated needle, double spring mechanism to ensure high puncture speed and eliminate needle vibrations. Sufficient to lance once: different colorcoded versions, right needle exposure length, adequate blood flow. Self-destructive mechanism excluding possibility of reuse, sterilized reliable sterility protector. 7141 Safety Lancet, Lite, 28G Needle, 1.5mm Depth, Purple, 200/bx 7142 Safety Lancet, Universal, 23G Needle, 1.8mm Depth, Blue, 200/bx 7143 Safety Lancet, Special, 17G Blade, 2.0mm Depth, Yellow, 200/bx 7155 Safety Lancet, Lite, 28G Needle, 1.5mm Depth, Purple, 100/bx 7156 Safety Lancet, Universal, 23G Needle, 1.8mm Depth, Blue, 100/bx 7157 Safety Lancet, Special, 17G Blade, 2.0mm Depth, Yellow, 100/bx HTL-STREFA MEDLANCE® PLUS EXTRA Patient skin is tough? More blood is needed? Reach for the Medlance® Plus Extra and collect over 10ul. 7045 Lancet, 2.4mm Penetration Depth, Needle 21G, Color Coding Green, 200/bx 7245 Lancet, 2.4mm Penetration Depth, Needle 21G, Color Coding Green, 100/bx HTL-STREFA MEDLANCE® PLUS LITE Collecting blood has never been so painless! Ideal for blood glucose monitoring purposes. 7043 Lancet, 1.5mm Penetration Depth, Needle 25G, Color Coding Purple, 200/bx 7243 Lancet, 1.5mm Penetration Depth, Needle 25G, Color Coding Purple, 100/bx HTL-STREFA MEDLANCE® PLUS SPECIAL Perfect for heel sticks on neonates and finger sticks on adults for high flow. Ultra sharp blade ensures adequate blood volume and quick healing. 7046 Blade 0.8mm, Penetration Depth 2.0mm, Color Coding Yellow, 200/bx 7246 Blade 0.8mm, Penetration Depth 2.0mm, Color Coding Yellow, 100/bx HTL-STREFA MEDLANCE® PLUS UNIVERSAL Whenever you need larger blood samples for testing glucose, hemoglobin, cholesterol, blood type studies, coagulation, blood gas and many others. 7044 Lancet, 1.8mm Penetration Depth, Needle 21G, Color Coding Blue, 200/bx 7244 Lancet, 1.8mm Penetration Depth, Needle 21G, Color Coding Blue, 100/bx SLB200 SLB250 SLN100 SLN200 SLN240 SLN300 MEDIPURPOSE - SURGILANCE SAFETY LANCETS Innovative, patented design provides safe and easy micro sampling in low, medium and high blood flow. Color coded for depth of penetration and easy identification. High-speed penetration minimizes patient pain and clinician error. Needles or blades are OSHA compliant, fully concealed before and after use. Ideal for all POC tests requiring whole blood samples, including glucose, cholesterol, HIV and more. Latex-free and hypoallergenic. Safe, simple and effective. SLB200 Blade, 1.8mm Penetration Depth, 19 Gauge, 75 to 100uL (High Blood Flow), Green, 100/bx SLB250 Blade, 2.3mm Penetration Depth, 18 Gauge, 150-200uL (High Blood Flow), Blue, 100/bx SLN100 Needle, 1.0mm Penetration Depth, 26 Gauge, 5-10ul (Low Blood Flow), Yellow, 100/bx SLN170 Needle, 1.7mm Penetration Depth, 28 Gauge, 5-10μl (Low Blood Flow), Lime, 100/bx, 15 bx/cs SLN200 Needle, 1.8mm Penetration Depth, 23 Gauge, 10-20uL (Low Blood Flow), Gray, 100/bx SLN240 Needle, 2.2mm Penetration Depth, 22 Gauge, 20-40uL (Medium Blood Flow), Orange, 100/bx SLN300 Needle, 2.8mm Penetration Depth, 21 Gauge, 40-60uL (Medium-High Blood Flow), Pink, 100/bx OWEN MUMFORD UNISTIK® 3 PRE-SET SINGLE USE SAFETY LANCETS Lancet is pre-set and does not require any cocking procedure. Just twist off the protective sterile cap and use. The needle point is hidden before use and automatically retracts after use to avoid accidental needle stick injuries and cross-infection. The unique, patented design features a side release button and pre-set lancet speed to ensure maximum comfort for the patient and the healthcare worker. AT1002 Lancet, Normal, 23G, 1.8mm Penetration Depth, Yellow, 100/bx AT1003 Lancet, Normal, 23G, 1.8mm Penetration Depth, Yellow, 1000/cs AT1004 Lancet, Normal, 23G, 1.8mm Penetration Depth, Yellow, 200/bx AT1007 Lancet, Normal, 23G, 1.8mm Penetration Depth, Yellow, 50/bx


2013_NDC_PhysCatalog
To see the actual publication please follow the link above